The switch has 4 physical queues that you can map to the 8 priority levels. On the switch, traffic assigned to higher index queues gets through faster while traffic in lower index queues is dropped if the network is congested. Page 55 Spanning Tree Protocol: Use STP to detect and disable network loops and provide backup links between switches, bridges or routers.
Page Ip Setup 5. The factory default IP address is The subnet mask specifies the network number portion of an IP address. The factory default subnet mask is Click Apply to save your changes back to the switch. Click Cancel to begin configuring this screen afresh. You may configure any of the 26 Ethernet ports ports 25 and 26 are uplink ports by clicking its index number. Page Ieee You must enable Page Table Port Edit Screen 2 at any one time.
A sixth device would have to wait until one of the five learned MAC addresses aged out. MAC-address aging out time can be set in the Switch Setup screen. Page 64 Specify how often a client has to re-enter his or her username and Timer password to stay connected to the port. Click Apply to save your changes back to the switch or click Cancel to begin configuring this screen afresh.
Gateway Address This field displays the IP address of the gateway. The gateway is an immediate neighbor of your switch that will forward the packet to the destination. Metric This field displays the cost of transmission for routing purposes. Page Static Route Edit Setup 1 and In practice, 2 or 3 is usually a good number. Figure Static Route Edit Setup You may choose to accept both tagged and untagged incoming frames or just tagged incoming frames on a port.
Page Configuring Tagged Vlans 8. If it does not form a VLAN with a particular port then the switch cannot manage that port. If it does not form a VLAN with a particular port then the switch cannot be managed from that port. This is for identification purpose only.
You may choose one port only or all ports All Ports. Destination The next three fields pertain to the destination MAC address and destination port. Page 82 Port Select the port to which the filter rule should be applied. Page Chapter 11 Mirror Setup Click Mirror Setup in the navigation panel to bring up the next mirror setup summary screen. Filter Setup To add a mirror rule, click this button. Port Select the port to which the filter rule should be applied.
Page 86 Port Select the port to which the filter rule should be applied. Page Bandwidth Control Setup This field displays whether the bandwidth control rule is activated or not. Bandwidth This field displays the maximum bandwidth allowed in kilobits per second for this traffic kbps flow. Page 90 Port Select the port to which the bandwidth control rule should apply. Page Chapter 13 Trunk Setup Ports should be physically linked in consecutive order without gaps when forming trunk groups.
For example ports 9, 10, 11 and 12 in switch 1 should connect to ports 1, 2, 3 and 4 in switch 2 to form one trunk group; ports 9, 10, 11 and 12 in switch 1 connected to ports 1, 3, 2, 4 in switch 2 would form two trunk groups, not one.
Page Figure Trunk Setup Make sure to select this check box to activate the trunk group. You may temporarily deactivate a trunk group without deleting it by clearing this check box. An agent is a management software module that resides in a managed switch the ES An agent translates the local management information from the managed switch into a form compatible with SNMP. The manager is the console through which network administrators perform network management functions. The manager issues a request and the agent returns responses using the following protocol operations: COMMAND Allows the manager to retrieve an object variable from the agent.
SNMP traps supported are outlined in the following table. For example, the following trap shows that the current reading at the 3. This key is not sent over the network. Page Chapter 16 Logins Configure up to four administrators using this screen Configure passwords for each administrator in the menu.
It is highly recommended that you change the default password "". Page Figure Edit Logins Login 1 to Login 4 and set a user name and password for each user as shown in the next screen and described in the previous three fields. The links on the upper right of the Maintenance screen lead to different screens that let you maintain the firmware and configuration files. None is the default value. Enter the time manually. Each time you turn on the switch, the time and date will be reset to Time Server IP Page Chapter 18 Firmware And Configuration File Maintenance Figure Firmware Upgrade Type the path and file name of the firmware file you wish to upload to the switch in the File Path text box or click Browse to display the Choose File screen from which you can locate it.
After you have specified the file, click Upload. After you have specified the file, click Restore. Be sure you keep unaltered copies of both files for later use. Page Chapter 19 Statistics Click Statistics in the navigation panel to open this screen. Use this screen to view general information and to access other screens with more detailed statistical information. Use this screen to view Spanning Tree Protocol information about the root bridge and this switch this switch may be the root bridge.
Hello Time second This is the time interval in seconds at which the root switch transmits a configuration message. Page Figure Hardware Monitor Use the hardware performance statistics in this screen for hardware troubleshooting. You may choose the temperature unit Centigrade or Fahrenheit in this field. Page Figure Poll Interval s The text box displays how often in seconds this screen refreshes. Page Figure Port Statistics This field displays the speed either 10M for 10Mbps, M for Mbps or another value depending on the uplink module being used and the duplex F for full duplex or H for half.
State This field displays the STP state of the port. Page Figure Port Details Select a port from the Port Details drop-down list box in the Statistics screen to display individual port statistics. Use this screen to check status and detailed performance data about an individual port on the card.
State This field shows the training state of the ports. Page Set Interval. Stop Click Stop to stop port statistic polling. Clear Counter Click this button to erase the recorded statistical information for this port.
Page Chapter 20 Diagnostic System Log Click this button to display a log of events in the multi-line text box. Display Click this button to restart the switch. A warning dialog box displays asking if you're sure. Click Reboot System OK to proceed. Clear System Log Click this button to clear the log of events in the multi-line text box.
Page Chapter 21 Commands Introduction It is recommended that you use the web configurator for everyday management of the switch and that you use line commands for advanced switch diagnosis and troubleshooting. Optional fields in a command are enclosed in square brackets [], for example, year, month and day are optional in the following command. Page Monitor Status Enables or disables the hardware monitor. Tests the hardware monitor chip. Performs an internal loop back test on a specified port or all ports.
Performs an external loop back test on a specified port or all ports. Displays the routing table. Adds a route. Adds an entry to the routing table for the specified interface. Adds a private route.
Multiple-play Applications. QoS and security protection. The ES Series offers premium features for excellent network. Robust and High- Availability System Design. The ES Series comes with comprehensive features to ensure round-the-clock operation.
With BPS support, power is supplied to the switch in case of an unexpected. The IEEE By utilizing. ES Series provides superior QoS capability to fully utilize the power of applications. In addition, the ES-. Previous Page. Next Page. Zyxel communications ethernet switch quick start guide 43 pages. The ES Series offers premium features for excellent network performances and ensures network stability.
At the same time, various network management options are available, like Web, telnet and the console port are supported. All rights reserved.
0コメント